FreeTender
Accepting bidstenderUnited States

Procurement of Benchtop Environmental Temp/Humidity Chamber

Issued by HEALTH AND HUMAN SERVICES, DEPARTMENT OF · FOOD AND DRUG ADMINISTRATION · FDA OFFICE OF ACQ GRANT SVCS · via SAM.gov — US federal contract opportunities

Published
21 Sept 2026
Closes
25 Sept 2026, 16:00 UTC
Reference
OC-2026-136029
Location
MA, United States
Sector
electronics-semiconductors

Details

HEALTH AND HUMAN SERVICES, DEPARTMENT OF · FOOD AND DRUG ADMINISTRATION · FDA OFFICE OF ACQ GRANT SVCS is soliciting Procurement of Benchtop Environmental Temp/Humidity Chamber. Solicitation number OC-2026-136029. Classified under NAICS 334513 — Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables. Product/service code 6636 — ENVIRONMENTAL CHAMBERS & RELATED EQ. Place of performance: MA, USA. Responses are due by 25 September 2026 16:00 UTC. Posted on SAM.gov, the US federal contract opportunities system; registration is required to bid.

Notice of Combined Synopsis/Solicitation. This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12. This announcement constitutes the only solicitation; quotes are being requested, and a separate written solicitation will not be issued. The NAICS for this requirement is: 334516. The government is not obligated to make an award. The Government is not obligated to pay costs incurred by the Contractor during quote preparation and quote submission. Background: The FDA laboratory at the Winchester Engineering Analytical Center (WEAC) uses an environmental chamber to condition regulatory samples (such as tampons, gowns, patches, etc.) at specific temperature and humidity levels before physical testing. The chamber also supports CDRH-directed research and test method development for other medical devices received by the laboratory for analysis. Minimum Performance Requirements/Salient Characteristics: This is a Brand Name or Equal requirement. Products other than the aforementioned are acceptable but shall meet all the salient characteristics contained in the Minimum Technical Requirements below: All of the following system requirements are minimum requirements. Equivalent requirements that differ from these minimum requirements shall be justified by the proposing vendor and evaluated by the WEAC prior to purchase: General The contractor shall provide an environmental chamber that uniformly conditions samples across a variety of temperature and humidity settings. The chamber must meet the following specifications:

  • Temperature range: at least -20°C to 180°C
  • Humidity range: 10% to 95% relative humidity (RH)
  • Capacity: 4 cu. Ft.
  • Power: Standard power cord and plug (no hardwiring)
  • Water supply: Easily accessible water supply connection
  • Humidity sensor: Solid-state humidity sensor
  • Leak Detection: Must have a water leak containment and detection system
  • Viewing window: For visual monitoring of samples
  • Interior shelf: At least one internal shelf
  • Mobility: Mobile cart with space-saving footprint (lab has no bench space and limited floor space for the chamber)
  • Cable port: At least one 2-inch diameter cable port with a flexible plug
  • Calibration: Factory calibration with an ISO 17025 certificate, or instrument calibration at start-up with ISO 17025 certificate
  • Warranty: At least one year

On-site Installation, Training and Commissioning

  • On-site installation and commissioning of the Environmental Chamber

Trade and Service Specification

  • All components shall be newly manufactured, not used or refurbished, and/or previously used for demonstration.
  • System installation shall occur after being received at the laboratory.
  • The entire system shall be warranted for parts and labor for a minimum of 12 months from date of formal government acceptance after on-site installation.
  • The warranty must include unlimited telephone/e-mail support for questions regarding operation.

Additional Section 508 Requirements:

• •

  • Must meet WCAG 2.0 A and AA
  • E101.2 Equivalent Facilitation (Appendix A, Application and Scoping Requirements)
  • E203 Access to Functionality (Appendix A, Application and Scoping Requirements)
  • E204 Functional Performance Criteria (Appendix A, Application and Scoping Requirements)
  • E205 Electronic Content (Appendix A, Application and Scoping Requirements)
  • 302 Functional Performance Criteria (Appendix C, Functional Performance Criteria and Technical Requirements)
  • Electronic content must be accessible to HHS acceptance criteria. Checklist for various formats are available at https://www.hhs.gov/web/section-508/making-files-

accessible/index.html, or from the Section 508 Coordinator listed at https://www.hhs.gov/web/section-508/additional- resources/section-508- contacts/index.html. Materials that are final items for delivery should be accompanied by the appropriate checklist, except upon approval of the Contracting Officer or Representative. • •

  • E208 Support Documentation and Services (Appendix A, Application and Scoping Requirements)
  • Chapter 6 Support Documentation and Services (Appendix C, Functional Performance Criteria
  • E206 Hardware (Appendix A, Application and Scoping Requirements)
  • Chapter 4 Hardware (Appendix C, Functional Performance Criteria and Technical Requirements) and Technical Requirements)
  • E207 Software (Appendix A, Application and Scoping Requirements)
  • Chapter 5 Software (Appendix C, Functional Performance Criteria and Technical Requirements)

Place of Performance:

The prospective vendor should provide insured shipping of equipment to: U.S. Food and Drug Administration, Winchester Engineering and Analytical Center (WEAC) Office of Specialty Laboratories and Enforcement Support 109 Holton Street Winchester, MA 01890

Period of Performance:

Performance begins on the date of formal government acceptance and continues through the end of the manufacturer's warranty period. Quotes are due by email on or before September 25 2026, by 12:00 P.M. (Eastern Standard Time) and should be sent to [contact details removed].

Context for bidders

We hold 30 notices from HEALTH AND HUMAN SERVICES, DEPARTMENT OF · FOOD AND DRUG ADMINISTRATION · FDA OFFICE OF ACQ GRANT SVCS, going back to August 202613 of them still open. They buy mostly in electronics-semiconductors, Financial & Professional Services and IT & Telecom. There are 1,088 open electronics-semiconductors tenders in United States. This one closes in 4 days.

Before you bid on this tender

A quick checklist to help you decide whether to bid and prepare a compliant submission for this electronics-semiconductors opportunity. Always verify the details on the official source.

  • Confirm the exact closing date and time (and time zone) on the official portal — deadlines are strict and can be revised by a corrigendum.
  • Read the full notice and every attached document, including the scope, specifications and any bill of quantities or terms of reference.
  • Check the eligibility criteria — prior similar experience, annual turnover, certifications and registrations — and make sure you qualify before investing effort.
  • Prepare any earnest-money deposit (EMD) or bid security and the required formats early; missing or wrongly-formatted documents are a common cause of rejection.
  • Note how bids must be submitted (online or physical), in what format, and whether a digital signature or portal registration is required.
  • Watch for corrigenda and clarifications right up to the deadline — requirements and dates can change.

More electronics-semiconductors tenders

All electronics-semiconductors tenders →

FreeTender mirrors this notice for reference. Verify the details and bid on the official portal.

Verify & apply on the official portal →