FreeTender
Accepting bidstenderUnited States

Gas Chromatograph with a Thermal Conductivity Detector and Flame Ioniztion Detector with Methanizer

Issued by COMMERCE, DEPARTMENT OF · NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY · DEPT OF COMMERCE NIST · via SAM.gov — US federal contract opportunities

Published
17 Sept 2026
Closes
21 Sept 2026, 16:00 UTC
Reference
1333ND26QNB640601
Location
MD, United States
Sector
electronics-semiconductors

Details

COMMERCE, DEPARTMENT OF · NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY · DEPT OF COMMERCE NIST is soliciting Gas Chromatograph with a Thermal Conductivity Detector and Flame Ioniztion Detector with Methanizer. Solicitation number 1333ND26QNB640601. Classified under NAICS 334516 — Analytical Laboratory Instrument Manufacturing. Product/service code 6630 — CHEMICAL ANALYSIS INSTRUMENTS. Place of performance: MD, USA. Responses are due by 21 September 2026 16:00 UTC. Posted on SAM.gov, the US federal contract opportunities system; registration is required to bid.

***Amendment 0001**** Amendment 0001 provides resposnes to questions received in response to the solicitation. Q.1.  I am reviewing Notice ID 1333ND26QNB640601 and would appreciate some clarification regarding the analytical requirements. Would you be able to share the analytes of interest, the required detection limits, and the expected concentration ranges for the system? A.1. This analyzer will be used for the analysis of binary gas mixtures in nitrogen or air balance gases. The analyses performed will include a wide range of gaseous standard reference materials including: 1 ppm methane in air and 250 ppm carbon monoxide in nitrogen, both analyzed using the flame ionization detector with methanation,  and 0.5 % carbon dioxide in nitrogen analyzed using the thermal conductivity detector. This analyzer will also be used for analyses of ambient level CO in air mixtures, ranging from (40 – 200) ppb. Q.2. What types of samples will be tested? A.2. This analyzer will be used for analyses of high pressure gas mixtures in nitrogen or air balance gases. Q.3. What specific substances or compounds need to be detected or analyzed in these samples? If available, please also share any specific testing standards or requirements. With this information, we can better understand your application and recommend a suitable instrument configuration and quotation accordingly. A.3. As stated above, this analyzer will be used for the analysis of high pressure gas mixtures delivered at or below 25 psig. The analyses performed will include a wide range of gaseous standard reference materials including: 1 ppm methane in air and 250 ppm carbon monoxide in nitrogen, both analyzed using the flame ionization detector with methanation,  and 0.5 % carbon dioxide in nitrogen analyzed using the thermal conductivity detector. For improved precision, temperature ramping and stable detector response are required to achieve baseline resolution between components in air balance gas. In all cases the repeatability should be at or below 0.2 % relative area counts. Q.4. Regarding your software requirements, you cite Visual Basic Version 6.0. Would that software be able to generate an XML file to communicate with our software (CompassCDS)? A.4. The visual basic software was developed to support communication between the GC software and a 12-port dead-end VICI sampling valve. The software can retrieve data from a txt file generated by the GC software and output the data to excel. There is not an extension to the solicitation as a result of this amendment. The question period for this soliciation will close today, September 17,2026, at 4:00 PM ET. End of Amendment 0001 ******** See attached.

Context for bidders

We hold 21 notices from COMMERCE, DEPARTMENT OF · NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY · DEPT OF COMMERCE NIST, going back to August 20267 of them still open. They buy mostly in electronics-semiconductors, Manufacturing & Supply and Financial & Professional Services. There are 922 open electronics-semiconductors tenders in United States. This one closes in 4 days.

Before you bid on this tender

A quick checklist to help you decide whether to bid and prepare a compliant submission for this electronics-semiconductors opportunity. Always verify the details on the official source.

  • Confirm the exact closing date and time (and time zone) on the official portal — deadlines are strict and can be revised by a corrigendum.
  • Read the full notice and every attached document, including the scope, specifications and any bill of quantities or terms of reference.
  • Check the eligibility criteria — prior similar experience, annual turnover, certifications and registrations — and make sure you qualify before investing effort.
  • Prepare any earnest-money deposit (EMD) or bid security and the required formats early; missing or wrongly-formatted documents are a common cause of rejection.
  • Note how bids must be submitted (online or physical), in what format, and whether a digital signature or portal registration is required.
  • Watch for corrigenda and clarifications right up to the deadline — requirements and dates can change.

More electronics-semiconductors tenders

All electronics-semiconductors tenders →

FreeTender mirrors this notice for reference. Verify the details and bid on the official portal.

Verify & apply on the official portal →